• JDZW3-36 outdoor epoxy resin casting Voltage transformer
JDZW3-36 outdoor epoxy resin casting Voltage transformer
discuss personally
Model
JDZW3-36
Basic info
Brand Wone Store
Model NO. JDZW3-36 outdoor epoxy resin casting Voltage transformer
Rated frequency 50/60Hz
Primary voltage 35kV
Secondary voltage 110V
Series JDZW
Product Detail

Product Overview

JDZW3-36 voltage transformer, outdoor epoxy resin casting and double pole insulated VT, is widely used for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50Hz or 60Hz and insulation voltage 36 kV (Up to 40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Excellent Outdoor Insulation Protection:JDZW3-36 uses high-quality epoxy resin as the main insulation material, with a silicone rubber coating on the outer layer. The internal traditional epoxy resin casting process ensures the transformer's insulation and electrical performance. Silicone rubber features excellent arc resistance, hydrophobicity, and climatic adaptability, enabling the equipment to operate normally in high-altitude, high-salt fog, rainy, and strong UV environments. Even if system faults cause explosions, the external silicone rubber structure restrains internal resin, reducing splashing damage to surrounding personnel, livestock, or equipment.

  • High Precision & Low Partial Discharge:The vacuum casting process achieves uniform electric field distribution with low partial discharge, enabling precise voltage measurement. Voltage ratio error is controlled within a minimal range, meeting high-precision metering and protection needs to provide reliable voltage data for 36kV and below power systems.

  • Fully Enclosed & Sealed Design:Primary and secondary terminals are completely sealed to prevent dust, moisture, and impurities from invading, avoiding electrical performance degradation caused by external factors. This extends service life and ensures stable operation in complex outdoor environments.

  • Strong Anti-Fouling Capability:The external insulation has high dry arc and large creepage distance, with creepage distance meeting or exceeding relevant standards—especially suitable for high-pollution areas. The surface undergoes special treatment to further enhance anti-fouling performance and reduce flashover risks.

  • Durable Metal Components:All metal components are hot-dip galvanized to enhance corrosion resistance, withstanding long-term outdoor exposure to wind, rain, and sunlight—ensuring reliable long-term service in outdoor environments.

Main technical parameter

  • Rated primary voltage:30 kV or 33 kV or 35 kV etc.

  • Rated secondary voltage:100 V or 110 V

  • Rated power-frequency withstand voltage: 70kV

  • Rated lightning impulse withstand voltage: 170kV

  • Technical standard accords with IEC 60044-2.2003.

  • Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!